RS-422/RS-485 COMMUNICATION MODULE

ACM12

Yokogawa ACM12 provides one RS-422 or RS-485 port for serial data exchange with subsystems such as PLCs. It supports half-duplex point-to-point or multipoint connections when used with the appropriate subsystem communication package.

PRODUCT TYPERS-422 / RS-485
OFFICIAL MODELACM12
PORT COUNT1 port
MODULE NESTAMN33
BRANDYokogawa
PRODUCT TYPERS-422/RS-485 Communication Module
CONDITION / WARRANTYOriginal New · One-Year Warranty
VERIFICATIONInstall ACM12 in an AMN33 communication nest. Use the appropriate subsystem communication package and match the serial settings to the connected equipment.
REQUEST A QUOTE
MODEL SEARCHFind a specific part numberOpen the best-matched Moore Automation product page directly.
PRODUCT INFORMATION● OFFICIAL YOKOGAWA REFERENCE
SERIAL SUBSYSTEM COMMUNICATION

ACM12

RS-422/RS-485 COMMUNICATION MODULE

1 port · Half-duplex · AMN33 nest

PRODUCT ROLE
ACM12 is a Yokogawa RS-422/RS-485 communication module. With a subsystem communication package, it exchanges serial data with subsystems such as PLCs through point-to-point or multipoint connections.
INSTALLATION CHECK
Install ACM12 in an AMN33 communication nest. Use the appropriate subsystem communication package and match the serial settings to the connected equipment.
👩‍💼
WANT THE BEST PRICE?
Frida
Sales Leader 🏆
EMAILsales5@mooreplc.comWHATSAPP+86 153 5940 8275
OFFICIAL YOKOGAWA REFERENCE

Technical Specifications

VERIFY COMPLETE MODULE REFERENCE
ACM12

Engineering data at a glance

Click “+” to expand more specifications.

PORT COUNT1 port
MAX SPEED19200 bps
MAX LENGTH1200 m
SUPPLY5.0 V DC
Installation requirement
ACM12 uses an AMN33 communication nest and a six-pole M4 screw terminal connection. ACM11 and ACM12 may share a nest; ACF11 must not be combined with them.
ManufacturerYokogawa
ModelACM12
Product typeRS-422/RS-485 Communication Module
InterfaceRS-422 or RS-485, 1 port
Connection topologyPoint-to-point or multipoint
Communication modeHalf-duplex
SynchronizationStart-stop
Current consumption1 A at 5.0 V DC
Communication speeds1200 / 2400 / 4800 / 9600 / 19200 bps
Transmission codeASCII or binary
Character length7 or 8 bits
Stop bit length1 or 2 bits
ParityNone, odd or even; no-parity setting unavailable at 19200 bps
Receive delay after transmission1 ms
Maximum transmission distance1200 m total length
Module nestAMN33 communication module nest
Signal connection6-pole terminals with M4 screws
Signal cable3-pair shielded cable
FA500 connection cableAKB161; maximum 100 m
Nest combinationACM11 may be combined with ACM12
Nest restrictionDo not combine ACM11/ACM12 with ACF11
System integrationRequires the applicable subsystem communication package
FAQ

ACM12 RS-422/RS-485 Communication Module FAQ

What does ACM12 do in a Yokogawa control system?+

ACM12 exchanges serial data with subsystems such as PLCs through one RS-422 or RS-485 port. The hardware works with the applicable subsystem communication package; its electrical interface alone does not define the application protocol.

Does ACM12 support multipoint communication?+

ACM12 supports both point-to-point and multipoint connections. Communication is half-duplex with start-stop synchronization, so the connected equipment must use matching serial settings and the appropriate subsystem communication package.

Which speeds and serial formats does ACM12 support?+

ACM12 supports 1200, 2400, 4800, 9600 and 19200 bps, ASCII or binary transmission, 7- or 8-bit characters and 1 or 2 stop bits. Match these settings to the connected subsystem.

Can ACM12 use no parity at 19200 bps?+

ACM12 provides none, odd and even parity selections, but Yokogawa excludes the no-parity setting at 19200 bps. At that speed, use an allowed parity setting that also matches the connected equipment.

What cable distance is specified for ACM12?+

ACM12 is specified for a maximum total transmission length of 1200 m with the documented serial wiring. The separately listed AKB161 cable for an FA500 connection has a maximum length of 100 m.

How is ACM12 installed and wired?+

ACM12 installs in an AMN33 communication module nest and connects through six-pole terminals with M4 screws. Yokogawa specifies three-pair shielded signal cable; the listed current consumption is 1 A at 5.0 V DC.

Can ACM12 share a nest with ACM11 or ACF11?+

ACM12 may share a communication nest with ACM11. Yokogawa prohibits combining ACM11 or ACM12 with ACF11 in that nest, so check the module allocation before adding or changing communication hardware.

CONTACT PRODUCT SPECIALIST

Check ACM12 application details with Frida

Provide the ACM12 nameplate, installed AMN33 nest, subsystem type, communication settings, required quantity and destination for application checking.

CHOOSE A DIRECT CONTACT METHOD
DATA SHEET

Official Hardware Specifications for
ACM12

Yokogawa GS 33G06K40-01E lists ACM12 explicitly. Page 15 provides its serial interface, communication settings, wiring, distance and current-consumption specifications.

ACM12 official hardware reference

The official multi-model I/O hardware specification identifies ACM12 as a single-port RS-422/RS-485 communication module. Use the ACM12 column on page 15; this document is a hardware reference, not a certificate for an individual supplied unit.

VIEW OFFICIAL SERIES PDF

Contact to Get Support

Send the ACM12 label, installed communication nest, subsystem type, serial settings, quantity and destination.

Reference: Yokogawa GS 33G06K40-01E, Communication Module, page 15. The document covers several I/O products; the ACM12 column defines this module's hardware data.

YOKOGAWA MODULE · MODEL IDENTIFICATION

How ACM12 Is Identified

Yokogawa identifies ACM12 as the RS-422/RS-485 communication module in GS 33G06K40-01E. The comparison below distinguishes the complete model from the separately listed ACM11; it does not assign meanings to individual characters.

Yokogawa · BRAND
ACM12 RS-422/RS-485 Communication ModuleOFFICIAL MODEL REFERENCE
RS-422 / RS-485 MODEL

ACM12

ACM12 provides one RS-422 or RS-485 port and supports point-to-point or multipoint communication. This is the requested module in the official comparison table.

DISTINCT RS-232C MODEL

ACM11

ACM11 is the separately listed single-port RS-232C module for point-to-point communication. Its interface and D-sub connection differ from ACM12.

Model relationship: ACM12 and ACM11 are separate module designations. For ACM12, use the RS-422/RS-485 column and its six-pole M4 screw terminal connection on page 15 of the official specification.
APPLICATION AREAS

Applications for ACM12

Serial Subsystem Integration

Serial data exchange with subsystems such as PLCs using the applicable communication package.

Point-to-Point Links

A single RS-422 or RS-485 port supports a point-to-point subsystem connection.

PRODUCT REFERENCEACM12Yokogawa RS-422/RS-485 communication module
Multipoint Serial Links

ACM12 supports half-duplex multipoint communication with start-stop synchronization.

AMN33 Nest Installation

Installs in an AMN33 communication nest with six-pole M4 screw terminal wiring.

ABOUT MOORE AUTOMATION

A trusted industrial automation sourcing partner

Moore Automation Limited supplies industrial automation spare parts to customers worldwide, with dedicated sourcing, part-number verification, pre-shipment confirmation and responsive sales support.

Global sourcing Pre-shipment verification One-year warranty
SERVICE

Industrial Automation Order Support

A clear workflow for sourcing, verification, shipment preparation, delivery and product assurance.

STAGESERVICE ACTIONWHAT WE CHECK OR PROVIDE
01PROCUREMENT
Product SourcingCurrent, hard-to-find and discontinued industrial automation parts.
02VERIFICATION
Part Number ReviewComplete model, suffix, nameplate, visible revision and application details.
03CONFIRMATION
Pre-Shipment CheckModel, label, condition and packaging confirmed with actual photos or video.
04FULFILLMENT
Global Delivery
Worldwide delivery with flexible shipping options. We support door-to-door pickup or delivery to your nominated freight forwarder in China.
DHLFedExUPSTNT
05ASSURANCE
One-Year WarrantyOne-year warranty from delivery for products supplied by Moore Automation.
Warranty Claim Information+
What to provide: If a product-related issue occurs within the warranty period, contact our team and submit one clear, continuous video for review.
✓Complete product and nameplate
✓Power supply and wiring connections
✓Installation and operating conditions
✓Indicator lights, alarms or error messages
✓Clear description of the fault
✓Continuous video showing the issue
Review outcome: If the evidence confirms a covered product fault, Moore Automation will arrange the appropriate warranty solution.
SALES ASSISTANCE

Contact Sales Manager Frida

Include the complete part number, quantity and delivery destination.

EMAILsales5@mooreplc.com WHATSAPP+86 153 5940 8275
dejar un mensaje
Si está interesado en nuestros productos y desea conocer más detalles, deje un mensaje aquí, le responderemos tan pronto como podamos.
  • SOCIEDAD ANÓNIMA
  • DCS
  • ETI
  • HMIS
Productos relacionados